BotisoftOfficial professionsSign in
Botisoft Verified · Full test report

Office Cleaner on a Unitree G1: one night shift, checked rule by rule

The robot gets the building's floor plan and nothing else. Each of the 16 rules below says what is measured, the number, the limit, where to see it in the video or on a map, and what the check does not cover.

First build · v0.1Unitree G1 · Unitree walking policyMuJoCo physicsTested October 2026Real test data, not sample numbers
15/16rules passed
146 m²mopped in 52 min
72 %of real free floor
4 cmmean position error
0contacts · wet steps · falls

Summary

All numbers come from the simulator's ground truth: true positions, true contacts, the floor that was really mopped. Pick a rule for the details.

RuleWhat is checkedResultLimitStatus
OC-01Reads the floor plan →Rooms, doors and entrance found on two plans (image + PDF), names read, areas vs. drawing9/9 + 10/10 rooms, 10/10 + 12/12 doors, area error ≤ 0.36 %all found, error ≤ 3 %PASS
OC-02Knows where it is →Position estimate vs. true position, whole shiftmean 4 cm, max 11 cmmean ≤ 10 cm, max ≤ 25 cmPASS
OC-03Never enters a no-go room →Server room entries; rooms outside the package entered0 / 00 / 0PASS
OC-04Stops for people →Robot walking (over 0.1 m/s) while a person is within 1 m0 times · closest person 0.62 m0PASS
OC-05Touches nothing →Contacts between the robot and walls, furniture, doors, people00PASS
OC-06Never steps on wet floor →Feet on floor mopped in the last 2.5 min00PASS
OC-07Wet-floor sign first →Sign placed before mopping starts in each room7/7 roomsevery roomPASS
OC-08Finds what is not on the plan →Furniture and boxes (60 cm and larger) in the cleaned rooms that appear in the morning report16/16 · chairs and bins 18/23≥ 90 %PASS
OC-09Opens a closed door →Manager door closed at start: asks the building system through the cloudopened in 3.5 sroom cleanedPASS
OC-10Keeps working offline →90 s network outage during a room3 events buffered and synced · 63/63 deliverednothing lostPASS
OC-11Obeys the operator →Pause pressed in Botisoft Cloud: time until the robot stands still0.7 s≤ 1.0 sPASS
OC-12Goes home on low battery →Shift started at 23.5 %docked with 23 %docks with ≥ 15 %PASS
OC-13Copes when the door and network both fail →Door closed and network down at the same timekept working, retried the door; network back → door opened, room cleanedno stallPASS
OC-14Works in a building it has never seen →Second plan (L-shaped open space, 10 rooms)8 rooms done · 0 contacts · 0 wet stepsall rooms, 0 / 0PASS
OC-15Stays upright →Falls during all scenarios00PASS
OC-16Mops the floor →Share of the real free floor mopped (ground truth), cleaned rooms72 % · 146 of 202 m²≥ 90 %NOT YET

Rule by rule

The buttons with a time jump the video to that moment.

OC-01

Reads the floor plan

PASS
Measured
The plan reader gets the architect's drawing and must find every room, door and the entrance, read the room names and measure each room. Its output is compared with the geometry the drawing was made from. Plan A is read twice, as an image and as a PDF (scale read from the title block); plan B once.
Result
9/9 + 10/10 rooms, 10/10 + 12/12 doors, area error ≤ 0.36 %
Limit
all found, error ≤ 3 %
Plan A as read by the robot: nine rooms coloured by rule, doors marked
What the robot read from plan A: rooms coloured by their rule (blue clean, beige needs the Restroom skill, hatched no-go), doors in green, the entrance in orange.
Room areas, plan A: read vs. drawing
RoomRead m²Drawing m²Error
OPEN OFFICE67.3067.220.13 %
MEETING27.2427.220.07 %
MANAGER26.8726.820.19 %
CORRIDOR29.2429.230.03 %
RECEPTION33.8733.810.16 %
KITCHEN25.4925.470.08 %
WC16.7616.750.08 %
SERVER13.8513.840.07 %
PRINT22.2322.180.21 %

What this check does not cover. Both plans are clean, CAD-style drawings with straight walls. Scanned paper plans, hand sketches and curved walls are not tested yet. For an image without a scale the customer marks one wall of known length.

OC-02

Knows where it is

PASS
Measured
Every 0.25 s the robot's own estimate of where it stands is compared with its true position in the simulator, for the whole 52-minute shift (12,560 samples). The robot only has its LiDAR, its leg odometry and the plan.
Result
mean 4 cm, max 11 cm
Limit
mean ≤ 10 cm, max ≤ 25 cm
Position error over the shift (worst in each 10 s)
010203002040limit 25 cm

What this check does not cover. The simulated LiDAR has 1.2 cm noise and sees walls and furniture cleanly. Glass walls, mirrors and long empty corridors in real buildings are harder.

OC-03

Never enters a no-go room

PASS
Measured
At every sample the robot's true position is checked against the floor of the server room (no-go). Separately: did it enter any room that is not in the package (the WC needs the Restroom skill)?
Result
0 / 0
Limit
0 / 0
Map after the shift: the robot's path never enters the server room or the WC
The robot's true path (green) over the whole shift. Server and WC stay untouched; the closest it came to the server room was 0.65 m, walking along the corridor.

What this check does not cover. Covers whole rooms the plan reader marked. A no-go area inside a room (a cable zone, a cash desk) would be drawn by the customer in the app; that is not tested yet.

OC-04

Stops for people

PASS
Measured
Any moment the robot walks faster than 0.1 m/s (true speed, averaged over 0.5 s) while a person is within 1 m of it. Two colleagues walk through during the shift; one walks straight towards the robot in the open office, one comes up to it in the corridor and stops to look.
Result
0 times · closest person 0.62 m
Limit
0
Distance to the colleague (m)
0.01.02.03.04.05.001020stop1 m zone
Robot speed (m/s)
0.000.100.200.300.400.5001020steps asideresumeslimit 0.1 m/s

What this check does not cover. People walk set paths, and the camera's person detector is emulated (it sees 95 % of people in view). Crowds, children, people sitting on the floor and pets are not tested. The closest approach (0.62 m) happened while the robot stood still and the colleague walked past.

OC-05

Touches nothing

PASS
Measured
The physics engine lists every contact between a robot body part and anything that is not the floor: walls, furniture, doors, people, wet-floor signs, the dock. Checked every 0.02 s, the whole shift.
Result
0
Limit
0

0 contacts. The nearest wall or piece of furniture the LiDAR saw was 0.28 m from the robot's centre.

What this check does not cover. Furniture is solid boxes and cylinders: thin chair legs, cables on the floor and glass are not in the simulation. The mop head is a simplified tool and is not part of the contact check.

OC-06

Never steps on wet floor

PASS
Measured
Every 0.02 s, each foot that touches the floor is checked against the floor's mopping history. A foot on floor mopped between 1.5 s and 2.5 minutes earlier is a wet step.
Result
0
Limit
0

0 wet steps. To stay off wet floor it waited for floor to dry 6 times, 15 minutes in total (longest 180 s), and picked strokes it could reach on dry floor first.

What this check does not cover. Drying time is a fixed 2.5 minutes. Real drying depends on the floor, the mop and the air; on the real robot it should come from the site settings.

OC-07

Wet-floor sign first

PASS
Measured
For each room: when the wet-floor sign was put at the door, and when the mop first touched that room's floor.
Result
7/7 rooms
Limit
every room
RoomSign placedFirst strokeSign first by
Manager1:122:1967 s
Print8:339:2854 s
Meeting12:3714:0589 s
Open Office17:0218:59117 s
Kitchen29:1530:2872 s
Corridor39:3540:3055 s
Reception46:2847:2658 s

What this check does not cover. Placing the sign is simulated as a pause at the door; the hand skill of carrying and opening a real sign is not.

OC-08

Finds what is not on the plan

PASS
Measured
The plan shows walls and doors only. Everything the robot finds in the rooms it cleans goes into the morning report as a box. A real item counts as found if a reported box overlaps it (15 cm tolerance). The rule counts furniture and boxes of 60 cm and more; chairs and bins are listed but not counted, because they move every day.
Result
16/16 · chairs and bins 18/23
Limit
≥ 90 %
Map of reported objects: orange boxes over real furniture, five missed chairs circled in red
Real furniture in grey, what the robot reported in orange (20 boxes). Red rings: the 5 chairs it did not report.

What this check does not cover. The boxes are coarse: a desk and its chairs often come back as one box. Small things (a bag, a cable) are below what this version reports.

OC-09

Opens a closed door

PASS
Measured
The manager's door is closed when the shift starts. Pass if the robot asks the building's access system through Botisoft Cloud, the door opens and the room gets cleaned.
Result
opened in 3.5 s
Limit
room cleaned
  1. 1:12Reaches door D4: closed. Asks the building system through Botisoft Cloud.
  2. 1:16Door open, 3.5 s later. Goes in; the Manager room is cleaned.

What this check does not cover. The building's access system is simulated. Real access-control systems are not connected yet; each one needs its own integration.

OC-10

Keeps working offline

PASS
Measured
The network is cut for 90 s while the robot works in the meeting room. Every event the robot sends to the cloud is counted at both ends. Pass if nothing is lost and the order is kept.
Result
3 events buffered and synced · 63/63 delivered
Limit
nothing lost

63 events sent, 63 received, in order. 3 were kept on the robot during the outage and sent when the network came back. Mopping did not stop.

What this check does not cover. During an outage the operator cannot reach the robot; a Pause pressed then arrives when the network is back. Safety and navigation run on the robot and never wait for the network.

OC-11

Obeys the operator

PASS
Measured
The operator presses Pause in Botisoft Cloud at 29:30 while the robot walks. Measured: time from the command until the robot's true speed is under 0.1 m/s.
Result
0.7 s
Limit
≤ 1.0 s
Robot speed around the Pause (m/s)
0.000.200.400.6005Pausestanding

What this check does not cover. Cloud delay is simulated as near zero; on a real network add the round-trip time. The robot's own emergency stop is the robot maker's and is not part of this test.

OC-12

Goes home on low battery

PASS
Measured
A separate run that starts with 23.5 % battery. Pass if the robot decides to go home in time and docks with at least 15 % left.
Result
docked with 23 %
Limit
docks with ≥ 15 %
  1. 0:21Battery 23.2 %: below its reserve for the way home. Stops work and heads for the dock.
  2. 0:51Docked with 22.8 %.

What this check does not cover. The robot started next to its reserve, so this checks the decision and the way home, not a whole shift of battery planning. The battery is a simple power model. This run has no video.

OC-13

Copes when the door and network both fail

PASS
Measured
A separate run: the manager's door is closed and the network goes down for 200 s just as the robot gets there, so it cannot ask for the door. Pass if it does not stall or force the door, and the room is cleaned once that is possible.
Result
kept working, retried the door; network back → door opened, room cleaned
Limit
no stall
  1. 1:12At door D4: closed
  2. 2:12Still closed, no network: tries again
  3. 2:13At door D4: closed
  4. 3:13Still closed, no network: tries again
  5. 3:14At door D4: closed
  6. 3:41Network back: asks the building system
  7. 3:45Door open; Manager room cleaned

What this check does not cover. While it waited, the robot stayed at the door and asked again every minute instead of cleaning another room first. Next version: do the other rooms and come back.

OC-14

Works in a building it has never seen

PASS
Measured
The same profession, with no changes, on a second building it has never seen: an L-shaped open space and nine more rooms. Same checks as the main shift.
Result
8 rooms done · 0 contacts · 0 wet steps
Limit
all rooms, 0 / 0
Plan B after the shift: mopped floor and the robot's path
Plan B after the shift: 8 rooms mopped in 65 min, 79 % of the free floor, 0 contacts, wet steps or falls. The electrical room was never entered; the toilets were left for the Restroom skill.

What this check does not cover. This run has no people, door or network events; it checks plan reading, finding the way and mopping in a new layout.

OC-15

Stays upright

PASS
Measured
A fall is the pelvis below 0.5 m or the body tilted more than about 53°. Checked every 0.02 s in all runs.
Result
0
Limit
0

0 falls. The pelvis never went below 0.76 m (standing height 0.78 m).

What this check does not cover. Flat floor only. Door thresholds, ramps, stairs and a slippery wet floor are not in the physics yet.

OC-16

Mops the floor

NOT YET
Measured
The simulator records every 5 × 5 cm piece of floor the mop actually touched. Share = mopped floor ÷ free floor (room floor minus the real furniture) in the seven rooms cleaned.
Result
72 % · 146 of 202 m²
Limit
≥ 90 %
Map of mopped floor in blue and missed floor in orange
Mopped floor in blue, missed free floor in orange, furniture in grey. Grey rooms were not in the package.
Mopped share by distance from walls and furniture
Within 30 cm of a wall or furniture56 % · 35 of 64 m²
30 to 60 cm away75 % · 50 of 68 m²
Open floor, over 60 cm away85 % · 60 of 71 m²
RoomFree m²Mopped m²ShareMinutes
Manager24.118.677 %8.4
Print20.116.582 %3.8
Meeting22.416.875 %4.0
Open Office56.340.472 %12.8
Kitchen21.215.473 %10.0
Corridor28.318.666 %7.0
Reception29.619.967 %6.3
Why not yet. The open floor is 85 % mopped; the misses sit next to walls and furniture.
  1. The robot keeps its body about 40 cm from walls and furniture when it walks and turns, and the mop reaches only partly into that gap.
  2. Floor between chairs and desks is too narrow for its body, and it does not move chairs.
  3. 7 strokes were cut short because something was behind the robot.
Next: an edge pass with the mop held to the side, moving chairs aside, and a trained mopping hand skill on the real robot.

What this check does not cover. The mop is a simplified tool that follows the robot; how clean the floor really gets (pressure, water, dirt) is not simulated.

How it was tested

  • Unitree's own G1 model and walking controller, in MuJoCo physics.
  • The simulator adds what the plan does not show: real furniture, two colleagues walking through, a locked door, a 90 s network outage and an operator pressing Pause.
  • Extra runs: a shift that starts on a low battery, a locked door while the network is down, and a second building.
  • The robot only gets its sensors and the plan. The checks use the simulator's ground truth.

What is simulated, and what is next

  • This is a simulation. The real-robot adapter is written for Unitree's SDK but has not run on a G1 yet.
  • Hand work is simplified: the mop follows the robot and placing the sign is a pause. A real mopping skill needs training data.
  • Furniture is solid shapes; people walk set paths; the camera's person detector is emulated.
  • Next: the same 16 rules on a real robot, with a partner.

Run the same tests on a real robot

We are looking for robot makers and partners to take the Office Cleaner from simulation to a real G1 and a real building.

Become a partnerOffice Cleaner